Overview

The TestSuite verify error handling response for PD communitcation between gateway to gateway. Bimodal test suite, test the service in both standard and passthrough and will call the JMX in the test case to switch service mode between standard and passthrough without application server restart.

This tests Gateway-406 (GW-949 is the testing subtask). See ticket for more details.

There are two things to test:

  1. If the requesting gateway encountered an error before the PD request is sent to the NwHIN
    (the error is local), then the gateway was not correctly populating the sender and receiver
    device\id@root. Now, the fields are populated with the actual gateway HCID.

  2. Error information is now populated in the XML tag controlActProcess\reasonOf
    detectedIssueEvent\text.a

TestCases Detail for standard and passthrough

The test cases is design to update the exchangeInfo PD service endpoint for gateway 2.2 to create communication error and verify the detected issue in the PD service response.

  • Patient Discovery bad URL: update exchangeInfo and verify detected issue.